Sign In | Join Free | My burrillandco.com
Home > C3 Grade Load Cell >

Weight Transmitter Load Cell Amplifier 0-5v 0-10v 4-20mA Signal Converter with and Voltage Current Amplifier

    Buy cheap Weight Transmitter Load Cell Amplifier 0-5v 0-10v 4-20mA Signal Converter with and Voltage Current Amplifier from wholesalers
     
    Buy cheap Weight Transmitter Load Cell Amplifier 0-5v 0-10v 4-20mA Signal Converter with and Voltage Current Amplifier from wholesalers
    • Buy cheap Weight Transmitter Load Cell Amplifier 0-5v 0-10v 4-20mA Signal Converter with and Voltage Current Amplifier from wholesalers
    • Buy cheap Weight Transmitter Load Cell Amplifier 0-5v 0-10v 4-20mA Signal Converter with and Voltage Current Amplifier from wholesalers
    • Buy cheap Weight Transmitter Load Cell Amplifier 0-5v 0-10v 4-20mA Signal Converter with and Voltage Current Amplifier from wholesalers
    • Buy cheap Weight Transmitter Load Cell Amplifier 0-5v 0-10v 4-20mA Signal Converter with and Voltage Current Amplifier from wholesalers
    • Buy cheap Weight Transmitter Load Cell Amplifier 0-5v 0-10v 4-20mA Signal Converter with and Voltage Current Amplifier from wholesalers
    • Buy cheap Weight Transmitter Load Cell Amplifier 0-5v 0-10v 4-20mA Signal Converter with and Voltage Current Amplifier from wholesalers

    Weight Transmitter Load Cell Amplifier 0-5v 0-10v 4-20mA Signal Converter with and Voltage Current Amplifier

    Ask Lasest Price
    Model Number : PY-V-SP
    Brand Name : Sensorcon
    Price : $22.50/pieces 1-19 pieces
    • Product Details
    • Company Profile

    Weight Transmitter Load Cell Amplifier 0-5v 0-10v 4-20mA Signal Converter with and Voltage Current Amplifier

    Weight transmitter 0-5v 0-10v 4-20mA output load cell amplifier


    Product List

    Sensorcon Product Lists
    Strain GaugeLoad CellTorque SensorDisplay
    Linear Strain gauge-AAWireless sensorSlip ring rotary torque sensorPlatform scale display
    Half bridge strain gauge-BB,HA,GB,FBMicro load cellContactless rotary torque sensorTruck scale display
    Shear/torque strain gauge-AB,HASingle point load cellStatic torque sensorController
    Full bridge strain gauge-EB, FG,FDButton load cellMetersJunction box
    Tee Rosettes strain gauge-CA,BAShear beam load cellCouplingBig screen display
    Round type strain gaugeS type load cellAmplifier
    Semi-conductor strain gaugeColumn load cell
    Bridge type load cell
    Product Overviews

    Weight transmitter 0-5v 0-10v 4-20mA output load cell amplifier


    Weight transmitter 0-5v 0-10v 4-20mA output load cell amplifier


    Size:


    Weight transmitter 0-5v 0-10v 4-20mA output load cell amplifier


    Features:

    Plastic housing, durable, cost-effective

    Housing and wire joints are waterproof design, good sealing

    High precision amplifier circuit, good stability

    Anti-jamming performance

    Wide sensitivity input range

    power supply with reverse protection, surge protection, overcurrent protection

    Sensor excitation voltage adjustable

    Portable, small size, light weight, easy to install

    Suitable for weighing, pull push force, torque, tension and other strain sensor


    Parameter


    Mode

    PY-V-SP

    Input Signal

    mV

    Sensitivity range

    Standard: 1MV/V, 1.5MV/V, 2MV/V, 3MV/V
    Optional: 0.5MV/V, 4MV/V, 5MV/V ,6MV/V

    Load cell Excitation Voltage

    5~15VDC(Adjustable)

    Operating Temperature

    -20~60

    Operating Humidity

    <90%RH

    Protection grade

    IP65

    Installation

    Housing fixing

    Housing material

    ABS

    Working Excitation voltage

    Standard: 12VDC, Optional: 24VDC

    Output signal

    Current:4~20mA, 0~10mA, 0~20mA

    Voltage:0~5V, 0~10V, 1~5V, ±5V, ±10V

    Please notify us which output you want when place order
    Customized output for voltage output is supported

    Accuracy

    Current output type ≥ 0.05%F.S

    Voltage output type ≥ 0.1%F.S

    Load cell connection

    At most 4 units of load cell in 350 ohm


    Connection:


    Weight transmitter 0-5v 0-10v 4-20mA output load cell amplifier


    Wire definition

    INPUT

    E+

    S+

    S-

    GND

    GNDD

    Load cell Input

    Load cell Exc +

    Load cell Signal+

    Load cell Signal-

    Load cell Exc -

    Shield

    OUTPUT

    24V

    Out

    GND

    GNDD

    Transmitter output

    Transmitter Exc+

    Transmitter Signal output

    Transmitter Exc-(0V)

    Shield

    VR

    Zero

    Span

    Sensor bridge voltage adjustment potentiometer

    ZERO C potentiometer

    Full-scale control point potentiometer

    I Zero-Current type, V Zero-Voltage type

    I Span-Current type, V Span-Voltage type


    Calibration:

    1. Excitation voltage regulation

    1.1 Transmitter 24V power supply,

    a) When output signal is 0-10mA, 0-20mA, 4-20mA, 0-5V, 1-5V and ± 5V,

    Excitation voltage is adjusted to 8-10.5V, (load ≤ 500Ω), factory default setting is 10.1V,

    b) When output signal is 0-10V, excitation voltage is adjusted to 11-12VDC, (load ≤ 500Ω), factory default setting is 11V;

    1.2 Transmitter 12V power supply

    When output signal is 0-10mA, 0-20mA, 4-20mA, 0-5V, 1-5V and ± 5V, the excitation voltage is adjusted to 6-8.5V, (load ≤ 320Ω), factory default setting is 8.01V

    1.3 User can adjust the "VR" according to actual situation. Adjust excitation voltage according to the sensor impedance but should not be higher than the max. Excitation voltage of load cell otherwise it will cause damage to the sensor or the sensor will not work properly.


    2. Zero adjustment

    First leave the system under no-load state, adjust the "ZERO" potentiometer to adjust the zero deviation.

    Till the indication is to zero.

    3. Gain adjustment

    Add certain weight to the system, (recommend 60% to 100% full scale), Calculate output value based on the ratio of added weight and the max. measuring value. Adjust the "SPAN" potentiometer till the indicator is to Load ratio indication

    4. Re-examination

    leave the system under no-load state, measure zero output; add certain weight, measure the output again and see whether it is in line with the expected gain. If not, please repeat steps 2, 3

    Note: After the adjustment is done, fix the end of the potentiometer with a sealant or glue to prevent any changing of potentiometer’s resistance from vibration

    Terms and Conditions

    1, in strict accordance with the definition of wiring, with particular attention to distinguish between the sensor and the output side, the wrong wiring may cause no output or damage.

    2, Except the potentiometer, all other electronic components should not have any change.

    3, the device should be installed to the place without vibration impact, the installation should be reliable, beware of bumps and no strong corrosive gas around

    Load cell Accessorie

    Weight transmitter 0-5v 0-10v 4-20mA output load cell amplifier


    Related Products

    Weight transmitter 0-5v 0-10v 4-20mA output load cell amplifierWeight transmitter 0-5v 0-10v 4-20mA output load cell amplifierWeight transmitter 0-5v 0-10v 4-20mA output load cell amplifier
    Weight transmitter 0-5v 0-10v 4-20mA output load cell amplifierWeight transmitter 0-5v 0-10v 4-20mA output load cell amplifierWeight transmitter 0-5v 0-10v 4-20mA output load cell amplifier
    Weight transmitter 0-5v 0-10v 4-20mA output load cell amplifierWeight transmitter 0-5v 0-10v 4-20mA output load cell amplifierWeight transmitter 0-5v 0-10v 4-20mA output load cell amplifier

    Company Information

    Sensor and Control Co., Ltd. was founded in 2006, mainly engaged in Torque Sensor, Load Cell, Pressure Transducer, Strain Gauges and Weighing Indicators. Since establishment, we insist the guidelines of "Customer Oriented, Quality Focused, Professional Service "All products we supply are environment friendly and has passed RoHS test.


    Sensorcon, in accordance with the principle of the introduction of advanced professional ultrasonic gas cleaning, clean Room patches, automatic temperature compensation and detection, high and low temperature testing and thermal experiments, laser welding and printing, CAD design, manufacturing and testing sensor test equipment and production technology ,manufacture all varieties of sensors, high precision, stable performance and also has antiseptic, waterproof, anti-explosion, anti-lightning, etc favored deeply by users.


    Weight transmitter 0-5v 0-10v 4-20mA output load cell amplifierWeight transmitter 0-5v 0-10v 4-20mA output load cell amplifier


    Packaging & Shipping

    Weight transmitter 0-5v 0-10v 4-20mA output load cell amplifier

    Contact Us

    Weight transmitter 0-5v 0-10v 4-20mA output load cell amplifier

    Quality Weight Transmitter Load Cell Amplifier 0-5v 0-10v 4-20mA Signal Converter with and Voltage Current Amplifier for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Hunan Jinlian Cloud Information Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)